Answer:
Energy Saved = 6.93 x 10⁹ Btu
Cost Saved = $ 30145.5
Explanation:
The energy generated by each boiler can be given by the following formula:
[tex]Annual\ Energy = (Heat\ In)(Combustion\ Efficiency)(Operating\ Hours)[/tex]
Now, the energy saved by the increase of efficiency through tuning will be the difference between the energy produced before and after tuning:
[tex]Energy\ Saved = (Heat\ In)(Efficiency\ After\ Tune - Efficiency\ Before\ Tune)(Hours)[/tex][tex]Energy\ Saved = (5.5\ x\ 3\ x\ 10^{6}\ Btu/h)(0.8-0.7)(4200\ h)[/tex]
Energy Saved = 6.93 x 10⁹ Btu
Now, for the saved cost:
[tex]Cost\ Saved = (Energy\ Saved)(Unit\ Cost)\\Cost\ Saved = (6.93\ x\ 10^{9}\ Btu)(\$4.35/10^{6}Btu)\\[/tex]
Cost Saved = $ 30145.5