Answer: 0.33
Explanation:
Process capability index (CPK) will be the minimum value between the following;
= [(Mean - Lower specification) / (3 * standard deviation)] and [ (Upper specification - Mean) / (3 * standard deviation)]
Lower specification = 1.1
Upper specification = 1.7
Mean = 1.5
Standard deviation = 0.2
= [(Mean - Lower specification) / 3 * standard deviation]
= [(1.5 - 1.1) / (3 * 0.2)]
= 0.67
= [ (1.7 - 1.5) / (3 *0.2)]
= 0.33
CPK = 0.33
A CPK of less than 1 means that Tyler will not be able to meet the tolerance limits as the process does not meet specifications.