One of the best ways to find a vacuum leak on a speed-density fuel-injection system is to read the intake air controller (LAC) count, or percentage, with a scan
tool. Normal IAC percentage is usually 15 to 25. A reading of less than indicates vacuum leak.
O A.5
OB. 10
O C.25
O D. 15

Respuesta :

Answer:

The correct option is A:

A) 5

Explanation:

One of the best way to know about the vacuum leak on a speed-density fuel injection is to look at IAC count or percentage. A reading less than 5 would indicate a vacuum leak. The extra air from the leak will result in:

  • Increase of Idle speed
  • MAP sensor interprets it as an additional load on the engine
  • Injector pulse width increases
  • IAC count decreases, trying to reduce engine speed to a previously set value
  • Air-fuel mixture remains the same
A should be the correct answer
ACCESS MORE