Given Data
Mass of refrigerant, m = 3.2kg
Work input to the cycle, Wnet = 27kj
The expression for coefficient of performance
C O P r = Q L /˙ W n e t ............(A)
The expression for maximum performance of refrigerator,
C OP r = T L /T H − T L . . . . . . . . . ( B )
Here, T L
is cold temperature reservoir, T H is hot temperature reservoir.
Since, T H = 2 T L . . . . . ( C )
Comparing equation (A) and (B),
Q L /˙ W n e t = T L /T H − T L
Substituting all the respective value in above equation,
˙
Q L /27 = T L /1.1T L − T L
Q L = 270kj
The expression for heat rejected,
Q H = W n e t + Q L
Q H=27 + 270
QH = 340kj