Answer:
Explanation:
a) From Gibbs phase rule F = C - P + 2
- C = number of components = 2 (MEK & air)
- P = number of phases = 2 ( liquid and vapor)
- Two variables need to be specified to fixed the system as this implies that the DOF = 2
- Where DOF = Degrees of freedom
b) Applying the Antoine equation
- log P x MEK = 6.97421 - 1209.6 / (T + 216)
- Plugging the values into the equation ; log P x MEK = 6.97421 - 1209.6 / (55 + 216) = 2.51
- Hence, Liquid and vapor phase are in equilibrium
Partial pressure of MEK = P*MEK = 323.59 mmHg
Mol fraction of MEK in vapor phase
- y = Partial pressure / equilibrium pressure
- = 0.269 which is greater than 0.115
Therefore, the value gotten is indicative that the given vessel won't constitute an explosion hazard.