Answer:
U = 129.053 KJ/m².h
Explanation:
overall heat transfer coefficient (U):
U = (mCp(ToutH2O - TinH2O))/[A((ToutAir - TinH2O)-(TinAir - ToutH2O))/(Ln(ToutAir - TinH2O)/(TinAir - ToutH2O))]
∴ A = 925 m²
H2O:
∴ mass flow H2O (m) = 45500 Kg/h
∴ Cp H2O = 4186 J/Kg°C
∴ Tin = 80°C
∴ Tout = 150°C
Air:
∴ Tin = 350°C
∴ Tout = 175°C
⇒ U = ((45500Kg/h)(4186J/Kg°C)(150-80))/(925m²)[((175-80)-(350-150))Ln((175-80)/(350-150))]
⇒ U = (1.333 E10 J/h)/(925m²)[(-150)Ln(0.475)]
⇒ U = 129052.73 J/m².h = 129.053 KJ/m².h